FRP Grating and Cable Tray in Sewer Infrastructure: Solving the H2S Corrosion Problem in Thames Tideway and AMP8 Projects
Underground sewer infrastructure presents one of the most aggressive material environments in civil engineering. Hydrogen sulphide generated by anaerobic bacterial activity in wastewater corrodes steel and concrete surfaces above the waterline in sewer tunnels, attacking the crowns of concrete sewers, the access grating and platforms inside pumping stations, and the structural and cable management infrastructure of wastewater treatment works. The Thames Tideway Tunnel, the largest new sewer infrastructure project in London in 150 years, runs for 25 kilometres beneath the Thames and connects to a network of combined sewer overflow infrastructure that itself requires ongoing maintenance and access. At scale, the access grating, cable management, and structural infrastructure inside sewer tunnels, pumping stations, and wastewater treatment works represents a substantial inventory of metallic and concrete materials in a continuous H2S, moisture, and microbially induced corrosion environment. FRP grating, cable tray, and handrail replace that inventory with materials that are immune to the specific corrosion mechanisms of the sewer environment and that maintain their structural and functional properties for the design life of the infrastructure without the maintenance cycles that steel and concrete impose in the same conditions.
Published by Reinforce Technology | 12 November 2026
The Thames Tideway Tunnel was constructed at a cost of approximately £4.5 billion and became fully operational in 2025, intercepting combined sewer overflows that previously discharged raw sewage into the Thames during heavy rainfall and directing them to Beckton sewage treatment works for treatment. The 25-kilometre tunnel at depths of up to 65 metres below the Thames riverbed is itself a civil infrastructure achievement, but the operational infrastructure within it, including the access and maintenance systems, cable management for electrical and monitoring services, and the connection chambers and shaft structures at each of the 24 connection points along its route, represents the ongoing asset that Thames Water's operational teams will maintain for the next hundred years. For the access grating, handrail, and cable management within that operational infrastructure, the material specification chosen at construction determines the maintenance burden carried by the asset for its full operational life (IntechOpen, 2022).

Hydrogen Sulphide and Microbially Induced Corrosion in Sewers
The corrosion mechanism that destroys steel and concrete infrastructure inside sewer tunnels and pumping stations is distinct from the chloride-induced corrosion that damages coastal and water treatment structures, and it is in some respects more aggressive. Anaerobic sulphate-reducing bacteria in the wastewater flowing through a sewer generate hydrogen sulphide as a metabolic product. That H2S dissolves into the biofilm coating the surfaces of the sewer above the waterline, where aerobic sulphur-oxidising bacteria oxidise the dissolved H2S to sulphuric acid. The sulphuric acid attacks the calcium silicate hydrate phases of Portland cement concrete, converting them to calcium sulphate and causing progressive loss of the concrete matrix, a process known as microbially induced corrosion or microbiologically influenced corrosion that can destroy unprotected concrete sewer linings at rates of several millimetres per year in high-H2S environments (ScienceDirect, 2023).
Steel access infrastructure inside a sewer, including grating panels, handrail posts and rails, cable tray, and structural support members, is subject to both direct H2S attack and to the sulphuric acid environment generated by microbially induced corrosion. Galvanised steel grating and handrail in a sewer pumping station or tunnel access chamber loses its zinc coating protection to the H2S and acid environment significantly faster than in an outdoor marine or industrial atmospheric environment, with the base steel corroding at accelerated rates once the galvanised coating is depleted. Even stainless steel grades that perform well in outdoor marine environments can be susceptible to pitting corrosion in the concentrated H2S and acid environment of a high-load sewer. FRP grating and structural systems contain no metallic element to corrode through any of these mechanisms: the glass fibre and resin composite is chemically inert in H2S, sulphuric acid at the concentrations found in sewer environments, and the full range of wastewater chemical constituents encountered in operational UK sewer infrastructure.
FRP Grating in Sewer Access Chambers and Pumping Stations
Access grating in sewer pumping stations, combined sewer overflow chambers, and tunnel access shafts is in continuous exposure to the H2S atmosphere of the sewer, the splashing and condensation of wastewater, and the aggressive cleaning agents used in routine maintenance of wastewater infrastructure. Steel grating in these environments requires inspection and replacement at intervals that are significantly shorter than the design life of the sewer structure itself, creating a recurring capital expenditure for the water company or infrastructure owner that accumulates substantially over the operational life of the asset. FRP moulded grating in vinyl ester resin grade resists the full chemical environment of a UK sewer pumping station at the concentrations encountered in operational conditions, providing the access and drainage function of the grating throughout the design life of the asset without corrosion-driven inspection and replacement cycles.
The open mesh geometry of FRP moulded grating is particularly well suited to sewer and pumping station access applications where drainage of wastewater splashing and hosing-down of deck surfaces is required. The 38x38mm and 50x50mm mesh sizes available in Reinforce Technology's moulded grating range provide the drainage aperture required for pumping station wet well access and sump drainage applications, and the grit surface moulded into the top face of the panels provides anti-slip performance in the wet and contaminated conditions of a working sewer access chamber without the applied anti-slip treatment that smooth steel plate access covers require. In confined sewer access chambers and manholes where the weight of the access cover or grating panel is a handling consideration for maintenance personnel entering and exiting the chamber, the lighter weight of FRP grating panels reduces the manual handling load relative to equivalent steel panels.
FRP Cable Management in Sewer and Wastewater Infrastructure
Sewer pumping stations, combined sewer overflow control structures, and wastewater treatment works carry extensive electrical and control cable systems for pump motor supply, variable speed drive power, level monitoring, telemetry, and emergency systems. The cable management infrastructure for these services is installed in the H2S, moisture, and chemical environment of the sewer and wastewater treatment facility, where the corrosion of metallic cable tray is driven by the same H2S and sulphuric acid mechanisms that attack steel access grating in the same location. FRP cable tray and ladder rack in sewer and wastewater applications provides a non-conductive cable management system that resists the sewer chemical environment without protective coating, eliminating the earthing and bonding requirement of metallic cable tray and removing the corrosion-driven maintenance of the cable management system from the facility's maintenance programme.
Non-conductive FRP cable tray in electrical pump motor rooms and variable speed drive installations within pumping stations also removes the risk of inadvertent electrical contact with the cable management structure in locations where high-current motor power cabling and low-voltage control and monitoring cabling are managed in close proximity. In wet environments where condensation and wastewater splashing creates moisture on cable tray surfaces, the non-conductive property of FRP cable tray is a direct safety advantage over metallic systems that may carry a voltage to earth if the cable insulation is compromised in the same wet environment.
AMP8 and the UK Water Infrastructure Investment Programme
The Thames Tideway Tunnel is the flagship project of a broader programme of UK sewer and wastewater infrastructure investment that extends across the AMP8 regulatory period from 2025 to 2030. Ofwat's £104 billion AMP8 settlement includes substantial capital investment in sewer capacity, combined sewer overflow reduction, and wastewater treatment works upgrade across all UK water companies, driven by regulatory requirements to reduce sewer overflow discharges to watercourses and to meet the requirements of the Storm Overflows Discharge Reduction Plan. New sewer tunnel construction, pumping station upgrade, and wastewater treatment works expansion projects across the UK water sector create a sustained pipeline of access grating, cable management, and handrail specification activity in which the chemical environment of sewer and wastewater infrastructure makes FRP the technically appropriate material specification for assets designed to perform for 50 to 100 years without the maintenance burden of steel alternatives in the same environment.
FRP Infrastructure from Reinforce Technology
Reinforce Technology supplies FRP moulded grating in 38x38mm and 50x50mm mesh sizes, pultruded GRP grating, FRP cable tray and ladder rack, FRP handrail systems, and FRP structural profiles for sewer tunnel, pumping station, combined sewer overflow, and wastewater treatment works access and cable management applications. Vinyl ester resin grade for enhanced H2S and chemical resistance in high-load sewer environments and polyester resin grade for general wastewater and outdoor applications are both available. Contact Reinforce Technology to discuss the grating specification, cable management configuration, or handrail system for your sewer or wastewater infrastructure project.
FRP grating, cable tray, and handrail specifications for sewer and wastewater applications should be confirmed against the specific H2S concentration, chemical composition, and temperature conditions of the installation. Vinyl ester resin grade is recommended for direct sewer exposure applications with elevated H2S concentrations. Reinforce Technology's technical team can advise on resin grade and product configuration for the specific chemical environment of the project.
References
IntechOpen (2022) 'Fibre-Reinforced Polymer (FRP) Composites in Civil Engineering Applications', in IntechOpen Engineering Series. Available at: https://www.intechopen.com/chapters/84203 [Accessed: 12 November 2026]. [FRP corrosion immunity in H2S, sulphuric acid, and microbially induced corrosion environments; vinyl ester resin grade chemical resistance in wastewater and sewer applications; non-conductive FRP cable tray in wet electrical environments; moulded grating drainage and anti-slip properties in pumping station and access chamber applications; design life of FRP grating and cable management systems in aggressive sewer chemical environments].
ScienceDirect (2023) 'Microbially induced corrosion of concrete and steel infrastructure in UK sewer systems: mechanisms, rates, and mitigation', Water Research, 243, pp. 1-18. Available at: https://www.sciencedirect.com/science/article/pii/S0043135423008456 [Accessed: 12 November 2026]. [Anaerobic sulphate-reducing bacteria H2S generation in wastewater; aerobic sulphur-oxidising bacteria sulphuric acid production on sewer crown surfaces; microbially induced corrosion rates in high-H2S UK sewer environments; galvanised steel coating depletion in H2S and sulphuric acid sewer atmospheres; stainless steel pitting corrosion susceptibility in concentrated sewer H2S environments; FRP chemical inertness in sewer H2S, sulphuric acid, and wastewater chemical environments].
Tideway (2023) Thames Tideway Tunnel: Project Overview and Operational Infrastructure. Available at: https://www.tideway.london/the-tunnel [Accessed: 12 November 2026]. [Thames Tideway Tunnel construction cost of approximately £4.5 billion; 25-kilometre tunnel depth up to 65 metres below Thames riverbed; 24 connection points along route; full operational commencement 2025; 100-year design life for operational infrastructure; connection to Beckton sewage treatment works; interception of combined sewer overflows previously discharging to Thames during rainfall events].




Comments